Adding product to the cart!
Added to the cart!
SUN-30/33/35/40/50/60K-G03 | 30-60kW | Three Phase | 4 MPPT
Description
Higher yields / Safe & Reliable / Smart / User-friendly
This series grid-tie inverter is preferred choice for commercial PV system. With the free-standing design, it greatly reduces installation time and costs. With a Max. 4 MPPTs design and Max. capacity of 50 kW, it is scalable up to the megawatt range.
4 MPP tracker, Max. efikasnost do 98,7%
Aplikacija za nulti izvoz, VSG aplikacija
Inteligentno praćenje nizova (opciono)
Širok raspon izlaznog napona
Tip II DC/AC SPD
Anti-PID funkcija (opciono)
Preuzmi tehničku dokumentaciju
>> Tehnička Dokumentacija <<>> Uputstvo <<
Model |
SUN-30K-G03 |
SUN-33K-G03 |
SUN-35K-G03 |
SUN-40K-G03 |
SUN-50K-G03 |
SUN-60K-G03 |
Input Side |
Max. DC Input Power(kW) |
39 |
42.9 |
45.5 |
52 |
65 |
78 |
Max. DC Input Voltage (V) |
1000 |
Start-up DC Input Voltage(V) |
250 |
MPPT Operating Range(V) |
200~850 |
Max. DC Input Current(A) |
40+40 |
40+40+40 |
40+40+40 |
40+40+40 |
40+40+40+40 |
40+40+40+40 |
Max. Short Circuit Current (A) |
60+60 |
60+60+60 |
60+60+60 |
60+60+60 |
60+60+60+60 |
60+60+60+60 |
Number of MPPT/Strings per MPPT |
2 / 3 |
3 / 3 |
3 / 3 |
3 / 3 |
4/ 3 |
4 / 3 |
Output Side |
Rated Output Power(kW) |
30 |
33 |
35 |
40 |
50 |
60 |
Max. Active Power(kW) |
33 |
36.3 |
38.5 |
44 |
55 |
66 |
Rated AC Grid Voltage(V) |
230 / 400 |
AC Grid Voltage Range(V) |
277Vac~460Vac(this may vary with grid standards) |
Rated Grid Frequency(Hz) |
50 / 60 (Optional) |
Operating Phase |
Three phase |
Rated AC Grid Output Current(A) |
43.5 |
47.8 |
50.7 |
58 |
72.4 |
87 |
Max. AC Output Current(A) |
47.9 |
52.6 |
55.8 |
63.8 |
79.7 |
95.7 |
Output Power Factor |
0.8 leading to 0.8 lagging |
Grid Current THD |
<3% |
DC Injection Current(mA) |
<0.5% |
Grid Frequency Range |
47~52 or 57~62 (Optional) |
Efficiency |
Max.Efficiency |
98.7% |
Euro Efficiency |
98% |
MPPT Efficiency |
>99% |
Protection |
DC Reverse-Polarity Protection |
Yes |
AC Short Circuit Protection |
Yes |
AC Output Overcurrent Protection |
Yes |
Output Overvoltage Protection |
Yes |
Insulation Resistance Protection |
Yes |
Ground Fault Monitoring |
Yes |
Islanding Protection |
Yes |
Temperature Protection |
Yes |
Integrated DC Switch |
Yes |
Remote software upload |
Yes |
Remote change of operating parameters |
Yes |
Surge protection |
DC Type II / AC Type II |
General Data |
Size(mm) |
647.5W×537H×303.5D |
Weight(kg) |
44.5 |
Topology |
Transformerless |
Internal Consumption |
<1W (Night) |
Running Temperature |
-25~65℃, >45℃ derating |
Ingress Protection |
IP65 |
Noise Emission(Typical) |
<45 dB |
Cooling Concept |
Smart cooling |
Max. Operating Altitude Without Derating |
2000m |
Designed Lifetime |
>20 years |
Grid Connection Standard |
CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11 |
Operating Surroundings Humidity |
0-100% |
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
Features |
DC Connection |
MC-4 mateable |
AC Connection |
IP65 rated plug |
Display |
LCD 240 × 160 |
Interface |